CCS Model Ordering Nomenclature:
Example: 604G1, where 604 -
Describes the Pressure Switch Model;
G
- Describes the Gage Pressure Switch;
1 - Describes the Adjustment Set-Point Range.
I. Letter Designations of Model Numbers:
A - Absolute Pressure Switch
D - Differential Pressure Switch
F - Flow Switch
G - Gage Pressure Switch
P - Piston Pressure Switch
T - Temperature Switch
V - Vacuum Pressure Switch
The optional letter designation could be inserted after the last letter in
the model number.
Example: 604GF1, F - means
that instead of the standard O-Ring compound, the Ethylene
Propylene "O"- Ring will be used in Wetted Parts.
II. Letter Designations of Electrical Assemblies:
A. The standard CCS model Part Number equipped with Non -
Explosion Proof Electrical (SPDT) switching element does not require any letter.
Example: 604G1 - means
standard switch with
(SPDT) switching element.
B. The standard CCS model Part Number equipped with Non-
Explosion Proof Electrical (DPDT) switching elements uses "M" letter designation
that could be inserted after switch model number
Example: 604GM1 - means
standard switch with
(DPDT) switching elements.
C. The standard CCS model Part Number equipped with Explosion
Proof & Hermetically-Sealed Elect. Assy. (SPDT) switching element does not
require any letter.
Example: 646GE1 - means standard
switch with
(SPDT) Explosion proof switching element
D. The standard CCS model Part Number equipped with (DPDT)
Explosion Proof & Hermetically-Sealed Elect. Assy. uses "M" letter designation
that could be inserted after the optional "E" Explosion Proof &
Hermetically-Sealed Elect. Assy.
Example: 646GEM1, M
-means
(DPDT) Explosion Proof & Hermetically-Sealed Elect. Assy.
E. The standard CCS model Part Number equipped with (DBL.BRK)
Explosion Proof & Hermetically-Sealed Elect. Assy. uses "X" letter designation
that could be inserted after the optional "E" Explosion Proof &
Hermetically-Sealed Elect. Assy.
Example: 646GEX1, M
-means
(DBL. BRK) Explosion Proof & Hermetically-Sealed Elect. Assy.
III. Letter Designations with Optional Features:
A - Viton "O"- Ring
(Wetted Parts only)
B - 1/4" Brass Pressure Port
C - Standard SST Capsule
E - Explosion Proof & Hermetically-Sealed Elect. Assy
F - Ethylene Propylene "O"- Ring
(Wetted Parts only)
H - Hermetically Sealed
J - CSA Approved
K - Extended Adjustment Knob
M - Dual (DPDT) Switch Circuit Utilizes Two SPDT Switch Elements
N -
TeflonŽ Encapsulated "O"-Ring (Wetted Parts only)
R - Manual Reset (Limited Usage)
W - Weatherproof
X - Double Break Switch Element (DBL. BRK.)
Y - ATEX/BASEEFA Certified (Explosion Proof for 646Y** Series only)
Z - SST Port Cap
The optional Switch Model options) described in the Suffix Table
could be inserted after the switch model.
Example:
604GF1-7008, 7008 - Describes the Gold
Contacts Switch Element.
|