Installation & Maintenance Instructions


10-1091.pdf
604G*, D*, P* Pressure Switch Series

10-1224.pdf
604DZ** -7011 Differential Pressure Switch Series (Russian Version)

10-1094.pdf
604T* Temperature Switch Series

10-1202.pdf
605G*, 605D*, 605P* & 605V* Pressure Switch Series

10-1116.pdf
611* Pressure Switch Series

10-1176.pdf
611GEY* & 611VEY* Pressure Switch Series 

10-1124.pdf
642DE* Differential Switch Series

10-1163.pdf
642GE*Y*, 642DE*Y*, 642VE*Y*  

10-1126.pdf
645DB* Differential Pressure Switch Series 

10-1093.pdf
646* Pressure Switch Series (English & Spanish Version) 

10-1115.pdf
646T* Temperature Switch Series

10-1153.pdf
646GE*Y*, 646DE*Y*, 646VE*Y*

10-1157.pdf
646GE*Y*, 646DE*Y*, 646VE*Y* (Spanish Version)

10-1181.pdf
646GE*Y*, 646DE*Y*, 646VE*Y* (Russian Version)

10-1154.pdf
646TE*Y* Switch Model

10-1150.pdf
672DE* Switch Model

10-1165.pdf
675GE*, 675DE*, 675VE*, 675GE800* & 675DE800* Pressure Switch Series

10-1168.pdf
675GEY*, 675DEY* & 675VEY* Pressure Switch Series

10-1180.pdf
675GEY*, 675DEY* & 675VEY* Pressure Switch Series (Russian Version)

10-1155.pdf
6403GE* & 6403DE* Pressure Switch Series

10-1159.pdf
6403TE*  & 6403TUE* Temperature Switch Series

10-1089.pdf
673DE* Differential Pressure Switch Series

10-1090.pdf
674D* Differential Pressure Switch Series

10-1170.pdf
674DEY* Differential Pressure Switch Series

10-1206.pdf
690P* & 690PE* Pressure Switch Series

10-1211.pdf
6900G* & 6900P* Pressure Switch Series

10-1196.pdf
6900G*-7075/7077 & 6900P*-7075/7077 Pressure Switch Series (Spanish Version)

10-1106.pdf
6900GE* & 6900PE* Pressure Switch Series

10-1166.pdf
6900GEY* & 6900PEY* Pressure Switch Series

10-1213.pdf
6900GEY* & 6900PEY* Pressure Switch Series (Spanish Version)

10-1200.pdf
6900GEY*-7089 & 6900PEY*-7089 Pressure Switch Series

10-1193.pdf
6900DEY* Pressure Switch Series

10-1218.pdf
6900DZE* Pressure Switch Series (Spanish Version)

10-1107.pdf
6900T* Temperature Switch Series

10-1186.pdf
6900TEY* & 6900TUEY* Temperature Switch Series

10-1214.pdf
6900TEY* & 6900TUEY* Temperature Switch Series (Spanish Version)

10-1095.pdf
6905G*, 6905D*, 6905P* Pressure Switch Series

10-1217.pdf
6905G* & 6905P* Pressure Switch Series (Spanish Version)

10-1209.pdf
6905GE*-7079 & 6905PE*-7079 Pressure Switch Series

10-1208.pdf
6905DZE* Pressure Switch Series

10-1216.pdf
6905DZE* Pressure Switch Series
(Spanish Version)

10-1096.pdf
6905TE*, 6905TUE* Temperature Switch Series

10-1178.pdf
6905* Pressure Switch Series (Russian Version)

10-1177.pdf
6905TE* Pressure Switch Series (Russian Version)

 

Acessories

10-1183.pdf
141-18, 141-19, 141-20 Junction Boxes

10-1187.pdf
141-21, 141-22 Junction Boxes

10-1184.pdf
89-130 Mounting Bracket 

 

 

CAUTIONS:
FOR INSTALLATION AND USE OF CCS PRESSURE, TEMPERATURE & FLOW SENSORS:

 

WARNING: If this switch is used to protect equipment or personnel from unsafe pressure or to guard against the hazardous release of contained substances, it must be installed and operated in accordance with applicable codes, regulations and standards. This switch must be used in conjunction with system design's (or procedure's) necessary to mitigate any hazard resulting from its failure. Conform to installation instructions accompanying this switch. Individuals who ignore this warning may suffer serious or fatal injury and do so at their own risk. Custom Control Sensors is not liable for any misuse, abuse, suitability or adequacy of user’s application of the switch. Service by qualified personnel only.

MEDIA: System media must be compatible with the specified wetted materials. Oxygen media cannot be utilized without special cleaning and packaging provided by the factory.  

OPERATING CONDITIONS: The electrical load, ambient temperature ranges, and proof pressure specified must not be exceeded. Surge pressurization should not exceed 200,000 psi per second to diaphragm switch models and 1 million psi per second to piston switch models. In installations that will be subject to severe shock, vibration, or other hostile environment conditions, contact the factory to determine suitability.

Field adjustable units should be set no closer than 1/2 turn from either end of their adjustment range.

UL/CSA/BASEEFA/SIRA/ATEX/IECEx: Field repairs or modifications of "certified" and "listed" units may void the listing of the repaired or modified unit. Effective August 2, 2005, CCS implemented Return Switch Authorization Policy. This policy will require that all products returned to CCS be identified with an RMA number assigned by CCS.