PRESSURE SWITCH TECHNICAL SUMMARY
This summary represents the standard technical parameters most commonly supplied to our customers. If the operating conditions of your specific application fall outside this data, we welcome the opportunity to review your requirements and make our recommendation.

MODEL SERIES 

1G 7G

7G PISTON

8G 8A

32G
32D
32V

41D 42G,
42D,
42V
44A 45D 75G
75D
75V
80G

90G PISTON

95G 98G

OPERATIONAL DATA                -STANDARD     ■-OPTIONAL

APPLICATION

PNEUMATIC

   
FUEL      
HYDRAULIC          
SWITCH TYPE
ABSOLUTE                                    
GAGE        
DIFFERENTIAL                       
VACUUM                               
EXPECTED SERVICE LIFE (CYCLES)
AT100% OF RANGE                                           
20,000 OR LESS                               
20,000-40,000                            
40,000-70,000                              

70,000-100,000

                         
100,000-150,000              
150,000-250,0000                             
250,000-500,000                          
PROOF PRESSURE RANGE (PSIG)
10-100                        
100-250                            
250-500                            
500-1000                         
1000-2000                              
2000-3000                               
3000-4000                               
4000-5000                       
5000-7500                               
7500+                         
SETTING RANGE
.25-30" H20                               
.5-15PSI                    
15-25                         
25-50                     
50-100                                
100-250                                          
250-500                 
500-1000                    
1000-1500                           
1500-2000                            
2000-2500                                        
2500-3000                               
3000-3500                               
3500-4000                               
4000+                                         
DEADBAND (PSI)

MIN: 10% OF SETTING OR MINIMUM AS SHOWN (WHICHEVER IS GREATER)

0.5 2 100 2 1 0.25 0.5 0.5 0.5 1 0.25 25 200 25 25

MAX. AS SHOWN

45% OF SETTING
TEMPERATURE RANGE:

 -65°F TO 165°F

STANDARD ALL MODELS

-65°F TO 300°F

AVAILABLE ALL MODELS

SHOCK RANGE (G)

(OPERATING)       10 OR LESS

                       
10-25                

25-50

                     
VIBRATION LIMITATIONS

(G) (LOADING) (0-2000) HERTZ         10

                         

15

                       

25

             

                                              25+

                         
ELECTRICAL RATING (STANDARD)

VOLTAGE:   DC

28 28 28 28 28 28 28 28 28 28 28 28 28 28 28

AC

250 250 250 250 125 250 250 250 250 250 250 250 250 250 250

AMPERES:

 RESISTIVE

5 5 5 5