PRESSURE SWITCH TECHNICAL SUMMARY
This
summary represents the standard technical parameters most commonly
supplied to our customers. If the operating conditions of your specific
application fall outside this data, we welcome the opportunity to review
your requirements and make our recommendation. |
|
MODEL
SERIES
|
1G |
7G |
7G PISTON
|
8G |
8A |
32G
32D
32V
|
41D |
42G,
42D,
42V |
44A |
45D |
75G
75D
75V |
80G |
90G PISTON
|
95G |
98G |
OPERATIONAL DATA
●-STANDARD
■-OPTIONAL |
| APPLICATION |
|
PNEUMATIC
|
● |
● |
|
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
● |
● |
| FUEL |
● |
● |
|
● |
● |
● |
● |
● |
|
● |
● |
● |
|
● |
● |
| HYDRAULIC |
|
● |
● |
● |
|
|
● |
● |
|
● |
|
● |
● |
● |
● |
| SWITCH
TYPE |
| ABSOLUTE |
|
|
|
|
● |
|
|
|
● |
|
|
|
|
|
|
| GAGE |
● |
● |
● |
● |
|
● |
|
● |
|
|
● |
● |
● |
● |
● |
| DIFFERENTIAL |
|
|
|
|
|
● |
● |
● |
|
● |
● |
|
|
|
|
| VACUUM |
|
|
|
|
|
● |
|
● |
|
|
● |
|
|
|
|
| EXPECTED
SERVICE LIFE (CYCLES) |
| AT100%
OF RANGE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 20,000
OR LESS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 20,000-40,000 |
|
|
|
|
|
|
|
|
● |
|
|
|
|
|
|
| 40,000-70,000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
70,000-100,000
|
|
|
|
● |
● |
|
|
|
|
|
● |
|
|
|
|
| 100,000-150,000 |
● |
● |
|
|
|
● |
|
● |
|
● |
|
● |
|
● |
● |
| 150,000-250,0000 |
|
|
|
|
|
|
● |
|
|
|
|
|
|
|
|
| 250,000-500,000 |
|
|
● |
|
|
|
|
|
|
|
|
|
● |
|
|
| PROOF
PRESSURE RANGE (PSIG) |
| 10-100 |
|
|
|
|
|
● |
|
|
● |
|
● |
|
|
|
|
| 100-250 |
|
|
|
|
|
|
|
● |
|
|
|
|
|
|
|
| 250-500 |
|
|
|
|
● |
|
|
|
|
|
|
|
|
|
|
| 500-1000 |
● |
|
|
|
|
|
● |
|
|
● |
|
|
|
|
|
| 1000-2000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2000-3000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3000-4000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 4000-5000 |
|
● |
|
● |
|
|
|
|
|
|
|
|
|
● |
● |
| 5000-7500 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 7500+ |
|
|
● |
|
|
|
|
|
|
|
|
● |
● |
|
|
| SETTING
RANGE |
| .25-30"
H20 |
|
|
|
|
|
● |
|
|
|
|
● |
|
|
|
|
| .5-15PSI |
● |
● |
|
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
| 15-25 |
● |
● |
|
● |
● |
|
● |
● |
● |
● |
|
|
|
|
|
| 25-50 |
● |
● |
|
● |
● |
|
● |
● |
● |
● |
|
|
|
|
|
| 50-100 |
● |
● |
|
● |
● |
|
● |
● |
|
● |
|
|
|
|
|
| 100-250 |
|
● |
|
● |
● |
|
|
|
|
|
|
|
|
● |
● |
| 250-500 |
|
● |
● |
● |
● |
|
|
|
|
|
|
● |
● |
● |
● |
| 500-1000 |
|
● |
● |
● |
● |
|
|
|
|
|
|
● |
● |
● |
● |
| 1000-1500 |
|
|
● |
● |
|
|
|
|
|
|
|
● |
● |
● |
● |
| 1500-2000 |
|
|
● |
|
|
|
|
|
|
|
|
● |
● |
|
● |
| 2000-2500 |
|
|
● |
|
|
|
|
|
|
|
|
● |
● |
|
● |
| 2500-3000 |
|
|
● |
|
|
|
|
|
|
|
|
● |
● |
|
● |
| 3000-3500 |
|
|
|
|
|
|
|
|
|
|
|
|
● |
|
● |
| 3500-4000 |
|
|
|
|
|
|
|
|
|
|
|
|
● |
|
|
| 4000+ |
|
|
|
|
|
|
|
|
|
|
|
|
● |
|
|
| DEADBAND
(PSI) |
|
MIN: 10% OF SETTING OR MINIMUM AS SHOWN
(WHICHEVER IS GREATER)
|
0.5 |
2 |
100 |
2 |
1 |
0.25 |
0.5 |
0.5 |
0.5 |
1 |
0.25 |
25 |
200 |
25 |
25 |
|
MAX. AS SHOWN
|
45%
OF SETTING |
| TEMPERATURE
RANGE: |
|
-65°F TO 165°F
|
STANDARD
ALL MODELS |
|
-65°F TO 300°F
|
AVAILABLE ALL MODELS
|
|
SHOCK RANGE (G)
|
|
(OPERATING)
10 OR LESS
|
● |
|
|
|
|
● |
|
|
|
|
● |
|
|
|
|
| 10-25 |
|
● |
|
|
|
|
● |
● |
● |
● |
|
|
|
● |
● |
|
25-50
|
|
|
● |
● |
● |
|
|
|
|
|
|
● |
● |
|
|
| VIBRATION
LIMITATIONS |
|
(G) (LOADING) (0-2000) HERTZ
10
|
|
|
|
|
|
● |
|
|
|
|
● |
|
|
|
|
|
15
|
|
|
|
|
|
|
|
● |
● |
● |
|
|
|
|
|
|
25
|
● |
● |
● |
|
|
|
● |
|
|
|
|
● |
● |
● |
● |
|
25+
|
|
|
|
● |
● |
|
|
|
|
|
|
|
|
|
|
| ELECTRICAL
RATING (STANDARD) |
|
VOLTAGE: DC
|
28 |
28 |
28 |
28 |
28 |
28 |
28 |
28 |
28 |
28 |
28 |
28 |
28 |
28 |
28 |
|
AC
|
250 |
250 |
250 |
250 |
125 |
250 |
250 |
250 |
250 |
250 |
250 |
250 |
250 |
250 |
250 |
|
AMPERES:
|
RESISTIVE |
5 |
5 |
5 |
5 |
| |